Torit 376 RF-12 Dust Collection System For Sale

Filtering

Reset All 

thru
 Used     New
Viewing Page 1 of 1
2 Results Found
Sort By 
STANDARD LISTINGS
1994 Torit 376 RF-12  Dust Collection System

TORIT 376RF12/CARTER DAY RJ Hybrid Dust Collection System with Rotary Air Lock & Transfer blower. -- General Data: Filter capacity 40,000 CFM @ 8:1 Air-to-cloth ratio, approx 140" dia. round baghouse with (324) filter bags of 12' length (oval bags provide for radial movement of bag during cleaning for longer life), total 5,054 sq. ft. filter area. -- Filter Cleaning: Filtration media cleaning via 7.5 HP medium pressure air pump (eliminates the need for compressed air which can be susceptible to condensation and freezing); 36" x 65" return air outlet and approx. 42" x 42" inlet for dust laden air. -- Includes: Rotating cleaning air manifold driven by 0.33 HP motor, (1) NEMA-9 solenoid and diaphragm valve which rotates over the bag openings, walk-in plenum for bag access/maintenance. Galvanized steel bag frames with positive bag bolt down to eliminate leakage and ride-up of bags once installed; walk-in acess door at top of ladder.. -- Complete with: Structural steel support, maintenance platform, caged ladder, bolt-on involute arm, explosion doors. -- Comes with: CSM 85HD Material Handling Blower with 150 HP TEFC motor currently setup for approx. 29,500 CFM @ 18" SP with VFD for 150 HP motor. Approx 24" Rotary Air Lock (RAL) at the bottom of the 60° hopper, ductwork from blower to baghouse. Transfer blower at discharge of RAL. -- Features: Fire Damper installed at outlet of baghouse for safety in case of fire., On roof level is a Summer/Winter diverter which is electrical operated. Inside building there is a perforated header pipe for sound/air distribution. -- Includes: Explosion doors, exterior piping and Variable Frequency Drive for 150 HP motor only. No starter/controls for remaining motors. NOTE 1: This hybrid unit is made up of a bottom section from a CARTER DAY RJ and top section of a DONALDSON/TORIT 376FR12. The RJ unit was slightly smaller in diameter hence the number of filters and area is slightly reduced fro (376) to (324). This composite unit is transparent and operates the same as a 376RF12 described above. The TORIT most representative model number is 324RF12.NOTE 2: The unit for sale on this record is pictured along the wall and in the middle of three units on 1st photo. -- UNIT AVAILABLE IN SEPT 2019.

Tony Cornacchione
800-374-5009 ext:432
Call

2015 Torit 376 RF-12  Dust Collection System

DONALDSON-TORIT 376RFW12 Dust Collection System with Automated/Monitoring Controls and loaded features. -- General Data: Filter capacity 45,800 CFM @ 8:1 Air-to-cloth ratio, approx 140" dia. round baghouse with (376) filter bags of 12' length (oval bags provide for radial movement of bag during cleaning for longer life), total 5,730 sq. ft. filter area. -- Filter Cleaning: Filtration media cleaning via 7.5 HP medium pressure air pump (eliminates the need for compressed air which can be susceptible to condensation and freezing); 36" x 65" return air outlet and approx. 42" x 42" inlet for dust laden air. -- Includes: Rotating cleaning air manifold driven by 0.33 HP motor, (1) NEMA-9 solenoid and diaphragm valve which rotates over the bag openings, walk-in plenum for bag access/maintenance.Galvanized steel bag frames with positive bag bolt down to eliminate leakage and ride-up of bags once installed; walk-in acess door at top of ladder.. -- Complete with: Structural steel support, maintenance platform, caged ladder, bolt-on involute arm, explosion doors. -- Comes with: CSM 85HD Material Handling Blower with 150 HP TEFC motor currently setup for approx. 29,500 CFM @ 18" SP with VFD for 150 HP motor. Fan/motor performance can be maximized/upgraded or 2nd fan/motor can be added to reach approx. 50,000 CFM (200+ HP), depending on application. Approx 24" Rotary Air Lock (RAL) at the bottom of the 60° hopper, ductwork from blower to baghouse. Transfer blower at discharge of RAL. -- Features: Fire Damper installed at outlet of baghouse for safety in case of fire., On roof level is a Summer/Winter diverter which is electrical operated. Inside building there is a perforated header pipe for sound/air distribution. -- Includes: Magnehelic gages, Explosion doors, exterior piping and Variable Frequency Drive for 150 HP motor only. No starter/controls for remaining motors. Outstanding Features: -- Updated design and animation of the main control panel’s touchscreen interfaces -- System overview graphics -- Alarms screens -- Start-up and shutdown setpoint configuration screens -- Automatic system start and stop controls -- Individual device start and stop controls -- Program has capability for "interlocked" start/stop control for two other filter units if installed at same premises. -- Program has automatic functionality allowing a sequential system start/stop (for two other filters) and variable blower control based on demand -- Variable frequency drive control via Ethernet -- Alarm conditions and responsesAlso available at extra cost is the complete GRECON fire detection/suppression system, controls, pressure tank.NOTE: The unit for sale in this record is pictured (on 1st photo), along the wall and on the left hand side of other units on other photos.. -- UNIT AVAILABLE IN SEPT 2019.

Tony Cornacchione
800-374-5009 ext:432
Call

Contact Us
  • Toll Free & Canada: (800) 477-7606
  • Direct & International: (931)381-1638
  • Location: 2508 Pillow Dr. Columbia, TN 38401
Copyright © 2019 LumbermenOnline.com - All Rights Reserved